A bipolar coaxial microprobe for safe transvitreal diathermy

Jean-Marie A Parel, G. E. O'Grady, R. Machemer

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

We present a new 22-gauge transvitreal bipolar diathermy microprobe. With the use of the coaxial principle, the current flows only at the probe's end surfaces. Because of its small size and end-on coagulation effect, and when used in conjunction with a low-frequency diathermy unit, the probe can be used safely on vessels lying directly on the retinal surface and close to the optic nerve head. We report three cases to demonstrate the usefulness of this instrument.

Original languageEnglish
Pages (from-to)494-497
Number of pages4
JournalArchives of Ophthalmology
Volume99
Issue number3
StatePublished - Jan 1 1981

Fingerprint

Diathermy
Optic Disk

ASJC Scopus subject areas

  • Ophthalmology

Cite this

A bipolar coaxial microprobe for safe transvitreal diathermy. / Parel, Jean-Marie A; O'Grady, G. E.; Machemer, R.

In: Archives of Ophthalmology, Vol. 99, No. 3, 01.01.1981, p. 494-497.

Research output: Contribution to journalArticle

Parel, J-MA, O'Grady, GE & Machemer, R 1981, 'A bipolar coaxial microprobe for safe transvitreal diathermy', Archives of Ophthalmology, vol. 99, no. 3, pp. 494-497.
Parel, Jean-Marie A ; O'Grady, G. E. ; Machemer, R. / A bipolar coaxial microprobe for safe transvitreal diathermy. In: Archives of Ophthalmology. 1981 ; Vol. 99, No. 3. pp. 494-497.
@article{1747ba912173494592643b0695aea589,
title = "A bipolar coaxial microprobe for safe transvitreal diathermy",
abstract = "We present a new 22-gauge transvitreal bipolar diathermy microprobe. With the use of the coaxial principle, the current flows only at the probe's end surfaces. Because of its small size and end-on coagulation effect, and when used in conjunction with a low-frequency diathermy unit, the probe can be used safely on vessels lying directly on the retinal surface and close to the optic nerve head. We report three cases to demonstrate the usefulness of this instrument.",
author = "Parel, {Jean-Marie A} and O'Grady, {G. E.} and R. Machemer",
year = "1981",
month = "1",
day = "1",
language = "English",
volume = "99",
pages = "494--497",
journal = "JAMA Ophthalmology",
issn = "2168-6165",
publisher = "American Medical Association",
number = "3",

}

TY - JOUR

T1 - A bipolar coaxial microprobe for safe transvitreal diathermy

AU - Parel, Jean-Marie A

AU - O'Grady, G. E.

AU - Machemer, R.

PY - 1981/1/1

Y1 - 1981/1/1

N2 - We present a new 22-gauge transvitreal bipolar diathermy microprobe. With the use of the coaxial principle, the current flows only at the probe's end surfaces. Because of its small size and end-on coagulation effect, and when used in conjunction with a low-frequency diathermy unit, the probe can be used safely on vessels lying directly on the retinal surface and close to the optic nerve head. We report three cases to demonstrate the usefulness of this instrument.

AB - We present a new 22-gauge transvitreal bipolar diathermy microprobe. With the use of the coaxial principle, the current flows only at the probe's end surfaces. Because of its small size and end-on coagulation effect, and when used in conjunction with a low-frequency diathermy unit, the probe can be used safely on vessels lying directly on the retinal surface and close to the optic nerve head. We report three cases to demonstrate the usefulness of this instrument.

UR - http://www.scopus.com/inward/record.url?scp=0019523480&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019523480&partnerID=8YFLogxK

M3 - Article

VL - 99

SP - 494

EP - 497

JO - JAMA Ophthalmology

JF - JAMA Ophthalmology

SN - 2168-6165

IS - 3

ER -